Disassembly of Outdoor Unit, continued
24,000 & 30,000 btuh Warning - Wait 10 minutes aer power is disconnected before starting disassembly.
13. Before electric box sub-assy
Remove the screws holding the isolation sheet, loosen wire binds,
pull out the terminals, then li to remove the electric box sub-
assy.
14. Remove PFC electrical inductance
Remove the screws holding the PFC electrical inductance and
isolation sheet, then remove the PFC electrical inductance.
15. Remove 4-way valve sub-assy.
Remove all refrigerant from unit. Unsolder the tubing connect-
ing the compressor, then condenser assembly. Remove the 4-way
valve assembly.
16. Remove suction pipe sub-assy
Unsolder the joints connecting the suction pipe sub-assy, then
remove the assembly.
17. Remove liquid receiver
Remove the screws holding the isolation sheet and liquid receiver,
then li receiver out.
18. Remove isolation sheet assy.
Remove he screws holding the isolation sheet and condenser side
plate to remove the isolation sheet.
4-way valve
sub-assy
PFC electrical inductance
Electric box sub-assy
Isolation sheet assy.
Liquid receiver