24
GRILLCHEF
Troubleshooting
If there is a fault despite due care, this chapter may help you to resolve the malfunction.
Malfunction Cause Remedy
There is a smell of gas Leak in the gas system 1. Close the cylinder valve immediate-
ly (turn G1 clockwise)
2. Prevent any ame or spark formati-
on (do not switch on any electrical
appliances)
3. Tighten all connections of the gas
system
4. Check all components of the gas
system for external damage; replace
defective parts with original spare
parts
5. Check for leaks using a leak detector
Burner does not light Gas cylinder is empty Replace the gas cylinder
Cylinder valve is closed Turn the cylinder valve (G1) anti-clock-
wise
Nozzles of the adjusting element
(underneath the front panel) are not
inserted into the burner hoses
Conduct a visual check, if necessary align
the nozzles and connection hoses
The igniter cable is not connected to
the Piezo igniter (A)
Conduct a visual test, connect if neces-
sary
Distance between the spark plug
and gas outlets on the burner (5) is
incorrect
Visual inspection; correct if necessary
Nozzle on adjusting element (under-
neath front panel) is blocked.
Remove the front panel and clean the
nozzle of the adjusting element using a
pin
Other gas system blocked The gas system should be cleaned by a
specialist
Temperature on grill too low Pre-heating time too short Close lid (1) and set ame regulator to
max. setting
Gas outlets on the burner (5) are
blocked
Remove blockages from burner