In accordance with the regulations outlined in IEC 61643-32 "Surge protective devices
connected to the d.c. side of photovoltaic installations - Selection and application
principles.", it is essential to implement lightning protection measures for both
household and commercial photovoltaic power plants.
The lightning protection measures for photovoltaic systems shall be
carried out in accordance with the corresponding national standards
and IEC standards. Otherwise, photovoltaic devices such as
components, inverters and power distribution facilities may be
damaged by lightning.
In this case, Growatt shall not be liable for the consequence and the
damage is not covered under any warranty.
Fig 6.14
6.7 Active power control with a smart meter or a ripple control
receiver
Information
Ø The smart meter should be installed between the inverter and the
gird.
Ø For details about the meter wiring, please refer to the manual of
the smart meter.
Inverters of this series support the export limitation functionality. To enable this function,
you can install a Growatt smart meter. For details, please contact Growatt support.
23
24
Smart meter models
No.
Meter Brand
Meter Pin No.
1
Chint
24,RS485A/25,RS485B
2
Eastron
A,RS485A/B,RS485B
3
Growatt
A,RS485A/B,RS485B
WARNING
Base Current (Ib)
10A
Power consumption
2W
Frequency
50/ 60Hz(±10%)
AC voltage withstand
4KV for 1 minute
Impulse voltage withstand
6KV-1.2uS waveform
Overcurrent withstand
20Imax for 0.5s
Pulse output 1
1000imp/kWh (default)
Pulse output 2
400imp/kWh
Display Max. Reading
LCD with white backlit 999999kWh
Environment
Operating temperature
-25to +55
Storage and transportation temperature
-40to +70
Reference temperature
23 ±2
Relative humidity
0 to 95%, non-condensing
Altitude
up to 2000m
Warm up time
3s
Installation category
CAT II
Mechanical Environment
M1
Electromagnetic environment
E2
Degree of pollution
2
Mechanics
Din rail dimensions
72x66x100 (WxHxD) DIN 43880
Mounting
DIN rail 35mm
Ingress protection
IP51 (indoor)
Material
self-extinguishing UL94V-0
10A
Manufacturer
Eastron
Type
SDM630CT-Modbus V3
General Specifications
Voltage AC (Un)
3*230V
Voltage Range
184~299V AC
Fig 6.15