U disk over-current
protection
1.Unplug the U disk.
2.Reconnect the U disk after shutdown.
3.If the error message persists, please contact
Growatt support.
1.After shutdown, check the fuse.
2.If the error message persists, please contact
Growatt support.
The DC input voltage
exceeds the upper
threshold
1.Immediately disconnect the DC switch and
check the voltage.
2.If the fault code persists after the voltage
restores to the acceptable magnitude, please
contact Growatt support.
1.Check the polarity of the PV input terminals.
2.If the error message persists, please contact
Growatt support.
1.Restart the inverter.
2.If the error message persists, please contact
Growatt support.
1.Restart the inverter.
2.If the error message persists, please contact
Growatt support.
1.Restart the inverter.
2.If the error message persists, please contact
Growatt support.
1.Check if the strings are securely connected.
2.If the error message persists, please contact
Growatt support.
String current
unbalanced
1.Check if the PV panel is working properly.
2.If the error message persists, please contact
Growatt support.
1.Check if a power outage occurs.
2.If the error message persists, please contact
Growatt support.
1.Check if the grid voltage is within the specified
range.
2.If the error message persists, please contact
Growatt support.
1.Check if the grid frequency is within the
specified range.
2.If the error message persists, please contact
Growatt support.
1.Please reduce the load of EPS output.
2.If the error message persists, please contact
Growatt support.
CT is open or
incorrectly wired
1.Check if the AC current sensor is connected
properly.
2.If the error message persists, please contact
Growatt support.
CT line reversed or
Ground fault
1.Check if the L line and N line of the CT are
reversely connected.
2.If the error message persists, please contact
Growatt support.
1.Check the connection of the communication
cable.
2.If the error message persists, please contact
Growatt support.
1.Check the connection of the communication
cable.
2.If the error message persists, please contact
Growatt support.
Meter is open or
incorrectly wired
1.Check if the Meter is connected properly.
2.If the error message persists, please contact
Growatt support.
Meter line reversed or
Ground fail
1.Check the L line and N line of the Meter is
reversed or not.
2.If the error message persists, please contact
Growatt support.
1.Check the PE cable to ensure that it is securely
connected.
2.If error message still exists, contact
Manufacturer.
No operation is required, the PCS will
automatically adjust the phase sequence.
1.After shutdown,check the connection of the
fan.
2.Replace the fan.
3.If the error message persists, please contact
Growatt support.
1.Check if the meter is on.
2.Check if the meter is correctly connected to
the inverter.
Communication
between the optimizer
and the inverter is
abnormal
1.Check if the optimizer is on.
2.Check whether the connection between the
optimizer and the inverter is normal.
String communication
abnormal
1.After shutdown,check the string panel wiring.
2.If the error message still exists, contact the
manufacturer.