Technical data
Ambient temperature
0-40 °C.
Ambient temperature during transport: -40 to
+70 °C.
Liquid temperature
Continuously: -10 to +110 °C.
Stainless steel pumps in domestic hot-water
systems:
In domestic hot-water systems, we
recommend that you keep the liquid
temperature below 65 °C to eliminate the
risk of lime precipitation.
Ambient temperatures below 0 °C
require the following conditions:
The media temperature is 5 °C.
The media contains glycol.
The pump runs continuously and
does not stop.
For twin-head pumps cascade
operation every 24 hours is
mandatory.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos 50 F Series and is the answer not in the manual?

Grundfos 50 F Series Specifications

General IconGeneral
Protection classIP55
Insulation classF
TypeCentrifugal pump
Pump housingCast iron
Impellerstainless steel
Frequency50 Hz / 60 Hz
Connection typeFlange
Speed2900 rpm
Liquid temperature-10°C to +120°C
Voltage230V or 400V