Maximum system pressure
The maximum permissible system pressure
is stated on the pump nameplate:
PN 6: 6 bar or 0.6 MPa
PN 10: 10 bar or 1.0 MPa
PN 16: 16 bar or 1.6 MPa.
Disposal
This product has been designed with focus
on the disposal and recycling of materials.
The following average disposal values apply
to all variants of MAGNA1 pumps:
85 % recycling
10 % incineration
5 % depositing.
This product or parts of it must be disposed
of in an environmentally sound way:
1. Use the public or private waste collection
service.
The actual inlet pressure and the
pump pressure against a closed valve
must be lower than the maximum
permissible system pressure.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos 50 F Series and is the answer not in the manual?

Grundfos 50 F Series Specifications

General IconGeneral
Protection classIP55
Insulation classF
TypeCentrifugal pump
Pump housingCast iron
Impellerstainless steel
Frequency50 Hz / 60 Hz
Connection typeFlange
Speed2900 rpm
Liquid temperature-10°C to +120°C
Voltage230V or 400V