EasyManua.ls Logo

Grundfos ALPHA2 Series - ALPHA SOLAR; Product Introduction and Application

Grundfos ALPHA2 Series
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English (GB)
31
12.3 ALPHA plugs
Fig. 44 ALPHA plugs
* This special cable with an active built-in NTC protection
circuit, reduces possible inrush currents. To be used in case of
for instance poor quality of relay components that are
sensitive to inrush current.
13. ALPHA SOLAR
13.1 Product introduction
Fig. 45 ALPHA SOLAR pump
13.2 Application
The new ALPHA SOLAR pump is designed to be integrated in all
kinds of solar systems with either matched-flow or constant-flow
rate.
13.3 Product description
High-efficiency ECM pumps, such as ALPHA SOLAR, must not
be speed-controlled by means of an external speed controller
which varies or pulses the supply voltage. You can control the
speed with a low-voltage PWM signal from a solar controller to
optimise the solar harvesting and temperature of the system. As a
result, the power consumption of the pump is reduced
considerably.
If no PWM signal is available, you can set the pump to constant
speed, only switched on and off by the controller.
13.4 Operating the product
13.5 Setting by means of the control panel
The user interface is designed with a single push button, one
red/green LED and four yellow LEDs.
.
Fig. 46 User interface with one push button and five LEDs
The user interface shows the following:
operating status
alarm status
settings view, after pressing the button.
13.6 Operating status
During operation, the display shows the actual operating status or
the alarm status.
13.7 Alarm status
If the circulator has detected one or more alarms, the red/green
LED switches from green to red. When an alarm is active, the
LEDs indicate the alarm type as defined in the table below. If
multiple alarms are active at the same time, the LEDs only show
the error with the highest priority. The priority is defined by the
sequence of the table.
When there is no active alarm anymore, the user interface
switches back to operating status.
TM06 5823 0216
Pos. Description
Product
number
Available
1
ALPHA straight plug,
standard plug connector,
complete
98284561 spare part
2
ALPHA angle plug, standard
angle plug connection,
complete
98610291 accessory
3
ALPHA plug, 90 ° bend to the
left, including 4 m cable
96884669 accessory
*
ALPHA plug, 90 ° bend to the
left, including 1 m cable and
integrated NTC protection
resistor
97844632 accessory
ALPHA SOLAR cables and plugs can be delivered
on request.
TM06 5816 0216
123
TM06 0535 0414
Push button LEDs

Table of Contents

Related product manuals