English (GB)
35
ALPHA SOLAR xx-145 130/180
* Only in minimum PWM speed operation
17. Disposing of the product
This product has been designed with focus on the disposal and
recycling of materials. The following average disposal values
apply to all variants of ALPHAx pumps:
• 92 % recycling
• 3 % incineration
• 5 % depositing.
Dispose of this product or parts of it in an environmentally sound
way according to local regulations.
For further information, see the end-of-life information at
www.grundfos.com.
Subject to alterations.
TM06 3652 0815
Note: PWM speed curves on request.
4>PñK@
>P@
+
>N3D@
S
4>OV@
4>PñK@
>:@
3
EEI ≤ 0.20 Part 3
P
L,avg
≤ 25 W
Setting Max. head
nom
Curve 1 6.5 m
Curve 2 8.5 m
Curve 3 10.5 m
Curve 4 14.5 m
Setting Max. P
1
nom
Curve 1 39 W
Curve 2 45 W
Curve 3 52 W
Curve 4 60 W
Electrical data, 1 x 230 V, 50 Hz Settings
Speed P
1
[W] I
1/1
[A] PWM C PP CP CC
Min. 2* 0.04 1 - - 4
Max. 60 0.58
TM06 6493 1516
TM06 5636 5115
Pump type
Dimensions [mm]
Connections Weight [kg]
L1 L3 B1 B2 H1 H2 H3
ALPHA SOLAR 25-145 180 180 90 72 45 25 103 128 G 1 1/2 2.0
H3
L1