29
13.2 Curve conditions
The guidelines below apply to the curves on the next pages:
Test liquid: Airless water.
The curves apply to a density of ρ = 983.2 kg/m
3
and a liquid
temperature of +60 °C.
All curves show average values and should not be used as guarantee
curves. If a specific minimum performance is required, individual
measurements must be made.
The curves for speeds I, II and III are marked.
The curves apply to a kinematic viscosity of υ = 0.474 mm
2
/s
(0.474 cSt).