EasyManuals Logo

Grundfos alpha2l User Manual

Grundfos alpha2l
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
28
13.1 Guide to performance curves
Each pump setting has its own performance curve (Q/H curve).
A power curve (P1 curve) belongs to each Q/H curve. The power curve
shows the pump power consumption (P1) in Watt at a given Q/H curve.
The P1 value corresponds to the value that can be read from the pump
display. See fig. 17:
Fig. 17 Performance curves in relation to pump setting
For further information about pump settings, see
6.3 Light fields indicating the pump setting
7. Setting the pump
10. Pump settings and pump performance.
TM04 2534 2608
AUTO
ADAPT
III
II
I
PP1
PP2
CP1
CP2
Q
P1
H
Q
III
II
I
ON
POWER
Setting Pump curve
PP1 Lowest proportional-pressure curve
PP2
(factory setting)
Highest proportional-pressure curve
CP1 Lowest constant-pressure curve
CP2 Highest constant-pressure curve
III Constant speed, speed III
II Constant speed, speed II
I Constant speed, speed I

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos alpha2l and is the answer not in the manual?

Grundfos alpha2l Specifications

General IconGeneral
Voltage230 V
Protection ClassIP42
Maximum Operating Pressure10 bar
Enclosure ClassIP42
Insulation ClassF
Pump HousingCast iron
TypeCirculator pump
Frequency50 Hz
ApprovalsCE
ConnectionG 1"
Ambient TemperatureUp to 40°C