EasyManuals Logo

Grundfos DME 150 Product Guide

Grundfos DME 150
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
30
Technical data
DME
DME (2 to 48)
Pump DME 2 DME 8 DME 12 DME 19 DME 48
Mechanical data
Maximum capacity without anti-cavitation
1
[l/h] 2.5 7.5 12 18.5 48
[GPH] 0.66 1.98 3.17 4.88 12.68
Maximum capacity with anti-cavitation
1
[l/h] 1.8 5.6 9 14.5 37
[GPH] 0.49 1.48 2.78 3.66 9.51
Maximum pressure
[bar] 18 10 6 6.2 2.6
[psi] 261 145 87 90 38
Maximum stroke frequency
2
[stroke/min]
180 180 180 151 151
Maximum wet/primed suction lift [ft (m)] 19.7 (6)
Maximum suction lift when priming with wet valves [m] 5.9 (1.8) 9.8 (3) 9.8 (3) 9.8 (3) 9.8 (3)
Maximum viscosity with spring-loaded valves
3
[cps]
500 500 500 500 100
Maximum viscosity without spring-loaded valves
3
[cps]
200 200 200 200 100
Maximum liquid temperature [F (°C)] 122 (50)
Minimum liquid temperature [F (°C)] 32 (0)
Maximum ambient temperature[F (°C)] 113 (45)
Minimum ambient temperature[F (°C)] 32 (0)
Accuracy of repeatability ±1%
Weight and size
Weight [lb (kg)] 5 (2.3) 5 (2.3) 5 (2.3) 7.5 (3.4) 7.5 (3.4)
Diaphragm diameter [in (mm)] 1.1 (28) 1.5 (38) 1.7 (43.5) 2.2 (55) 3.03 (77)
Electrical data
Supply voltage [V] 1 x 100-240 V, 50-60 Hz
Maximum current consumption [A]
at 100 V 0.27 0.35
at 230 V 0.16 0.26
Maximum power consumption P
1
[W]
16.2 22.1
Enclosure class IP 65
Insulation class F
Signal input
Voltage in level sensor input [VDC] 5
Voltage in pulse input [VDC] 5
Minimum pulse-repetition period [ms] 3.3
Impedance in analog 0/4-20 mA input [Ω] 250
Maximum loop resistance in pulse signal circuit [] 350
Maximum loop resistance in level signal circuit [] 350
Signal
output
Maximum load of alarm relay output, at ohmic load [A] 2
Maximum voltage, alarm relay output [V] 250
Sound pressure The sound pressure level of the pump is lower than 70 db(A).
Approvals CE, VDE, cUL, UL, METI
1
At any back-pressure within the pump’s specified range when calibrated to the actual installation.
2
The maximum stroke frequency varies according to calibration.
3
Maximum suction lift: 3 ft.
Dm123.book Page 30 Tuesday, February 8, 2005 8:24 AM

Other manuals for Grundfos DME 150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos DME 150 and is the answer not in the manual?

Grundfos DME 150 Specifications

General IconGeneral
BrandGrundfos
ModelDME 150
CategoryWater Pump
LanguageEnglish

Related product manuals