5. Startup of the product
WARNING
Electric shock
Death or serious personal injury
Do not use the product for cleaning and other
maintenance of swimming pools or similar places if
there are people in the water.
CAUTION
Hot surface
Minor or moderate personal injury
Use protective gloves if the liquid or ambient
temperature is higher than 104 °F (40 °C).
CAUTION
Hot surface
Minor or moderate personal injury
Do not run the pump continuously with a closed inlet or
outlet valve.
CAUTION
Hot or cold liquid
Minor or moderate personal injury
Make sure that escaping hot or cold liquid does not
cause injury to persons or damage to the equipment.
Do not turn on the power supply until the pump has been
filled with liquid.
The number of starts and stops must not exceed 20 times
per hour.
The pump must not run without delivering water for more
than 5 minutes.
Only use the product for the intended use and for the
pumped liquids stated in these installation and operating
instructions.
Related information
4.3.3 Setting the voltage converter
5.1 Priming the product
6.1.1 Intended use
6.2 Pumped liquids
5.1 Priming the product
Always tighten the priming plug by hand.
1. Unscrew the priming plug.
2. Fill the pump with water.
3. Refit the priming plug and tighten by hand.
1
3
2
TM074061
Fig. Priming the JP PS pump
Related information
5. Startup of the product
15
English (US)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Grundfos JP PS Series and is the answer not in the manual?

Grundfos JP PS Series Specifications

General IconGeneral
BrandGrundfos
ModelJP PS Series
CategoryWater Pump
LanguageEnglish

Related product manuals