5.1.2 Horizontal mounting of version H pumps
MTR, MTRE version H pumps are suitable for
horizontal mounting. The pump head is fitted with a
plug in the drain hole.
TM071679
Horizontally installed MTR version H pump
TM071680
Horizontally installed MTR version H pump with foot
support
Check the pump nameplate to confirm that the
pump is suitable for horizontal mounting.
The code for the pump version must be H. See
the section on type key
.
Check if the motor needs support. Motors from 5.5
kW and up have a foot and must be supported.
Fit a sealing gasket or similar between the pump
flange and the tank to prevent leakage.
Drain the tank before changing the shaft
seal.
Pump version H for horizontal mounting is
available for MTR, MTRE 1s, 1, 2, 3, 4, 5,
8, 10, 15 and 20. MTR, MTRE 32, 45, 64
pumps must be installed in a vertical posi-
tion.