3. Receiving the product
3.1 Performance test
The pumps are not tested for performance before leaving the
factory unless it was specifically ordered.
3.2 Transporting the product
WARNING
Overhead load
Death or serious personal injury
‐ Pay attention to the pump weight, and take
precautions to prevent personal injury if the pump
topples or falls by accident.
• Always transport the pump in the specified position.
• Securely fasten the pump to prevent damage to the shaft and
shaft seal caused by excessive vibrations and knocks.
• Do not lift the pump by the shaft.
3.3 Inspecting the product
• Confirm that the product received is in accordance with the
order.
• Confirm that the voltage, phase and frequency of the product
match the voltage, phase and frequency of the installation site.
See Identification.
• Check the product for defects or damages immediately upon
receipt. Any accessory ordered will be packed in a separate
container and shipped with the product.
• If any equipment is damaged in transit, report it immediately to
the carrier's agent. Make complete notations on the freight bill.
3.4 Storage after delivery
The contractor must inspect the equipment on delivery and make
sure it is stored so as to avoid corrosion or damage. See Storing
the product.
4. Installing the product
4.1 Mounting of motor on bare shaft pumps
4.1.1 Mounting of motor on pump housing without feet
The pumps are supplied with a transport bracket protecting the
shaft seal during transport. When you mount the motor, follow the
instructions and drawings as below.
1. Remove the coupling guard and loosen the set screws in the
shaft.
TM053327
2. Place the pump on the motor.
TM033906
3. Fit and tighten the motor screws to the correct torque. See
below.
• M8: 20 ± 4 Nm
• M10: 40 ± 8 Nm
• M12: 70 ± 15 Nm
• M16: 145 ± 30 Nm
• M20: 150 ± 30 Nm
• M24: 200 ± 40 Nm
TM033907
10