4.2 Location
CAUTION
Hot or cold surface
Minor or moderate personal injury
When pumping hot or cold liquids, make sure that no
one can accidentally come into contact with hot or cold
surfaces.
The pump must be sited in a well-ventilated, but frost-free location.
4.2.1 Vertical installation, NB
For inspection and repair, allow suitable clearances for
pump or motor removal.
Pumps fitted with motors up to and including 5 hp (4 kW) require
a 12 inches (0.3 m) clearance above the motor.
Pumps fitted with motors of 7.5 hp (5.5 kW) and up require at
least a 40 inches (1 m) clearance above the motor to allow the
use of lifting equipment.
A
TM085806
Clearance above the motor
Motor Minimum clearance, A
0.33 - 5 hp (0.25 -4 kW) 12 inches (0.3 m)
7.5 - 50 hp (5.5 -37 kW) 40 inches (1 m)
4.2.2 Horizontal installation, NB
For inspection and repair, allow suitable clearances for
pump or motor removal.
Pumps fitted with motors up to and including 5 hp (4 kW) require
a 12 inches (0.3 m) clearance behind the motor.
Pumps fitted with motors of 7.5 hp (5.5 kW) and up require a 12
inches (0.3 m) clearance behind the motor and at least a 40
inches (1 m) clearance above the motor to allow the use of
lifting equipment.
NB pumps with base frame must have the same clearance as
pumps with motors from 7.5 to 268 hp (5.5 to 200 kW).
A
TM085807
Clearance behind the motor
Motor Minimum clearance, A
0.33 - 5 hp (0.25 -4 kW) 12 inches (0.3 m)
B
A
TM085808
Clearance behind and above the motor
Motor
Minimum clearance
A B
7.5 - 268 hp (5.5 - 200 kW) 12 inches (0.3 m) 40 inches (1 m)