GSI Group - Laser Division
JK300HP/JK300P/JK125P
Issue 2.0 Pre-installation and User Manual
Part No: 1EA300E01 Page 89 of 172
Possible causes:
1. Faulty temperature sensor.
2. Loose connections.
3. Faulty Cooler Module.
7.5.14 Alarm 3n14: Conductivity Sensor Fault
Meaning:
The coolant conductivity sensor is faulty.
Possible causes:
1. Faulty conductivity sensor.
2. Loose connections.
3. Faulty Cooler Module.
7.6 Power Supply Alarms (Zone 4)
7.6.1 Alarm 4n01 : Power Supply Module communication fault
Meaning:
Power Supply n stopped communicating on the laser control network.
Possible causes:
1. Incorrect laser type specified.
2. Power Supply not fitted.
3. Loose laser control network connections.
4. Re-programming Power Supply.
5. Faulty Power Supply.
7.6.2 Alarm 4n02 : Power Supply Software Error
Meaning:
The power supply control software failed to initialise.
Possible causes:
1. Faulty power supply.
7.6.3 Alarm 4n03 : Power Supply Negative 15 Volt Fault
Meaning:
The negative 15 Volt supply for the internal power supply control has failed.
Possible causes:
1. Faulty power supply.
7.6.4 Alarm 4n04 : Power Supply Fan Fault
Meaning:
The power-supply cooling-fan is either running too slowly, or has stopped.
Possible causes:
1. Faulty power supply (faulty fan).
Petitioners Canadian Solar Inc. and Canadian Solar (USA) Inc.
Ex. 1025, p. 89

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GSi JK300HP and is the answer not in the manual?

GSi JK300HP Specifications

General IconGeneral
BrandGSi
ModelJK300HP
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals