7.3.12 Alarm 1n12 : Laser Type Not Recognised By The Laser Control Network
Meaning:
The Interlock Module did not receive a correct laser type over the laser control network
following a request.
Possible causes:
1. New laser control card.
2. Re-Programmed laser control card.
3. Loose Laser Control Network connections.
4. Faulty Interlock Card.
5. Faulty Laser Control Card.
7.3.13 Alarm 1n13 : LCC DSP Communications Fault
Meaning:
The Laser Control Card DSP has stopped communicating with the Laser Control Card
Neuron device.
Possible causes:
1. Laser Control Card DSP not programmed.
2. Loose Laser Control Network connections.
3. Faulty Laser Control Card.
7.3.14 Alarm 1n14 : Unexpected power down
Meaning:
The Laser power failed while the laser was on.
Possible causes:
1. Power failed while laser was on
2. Faulty Laser Control Card.
7.4 Interlock Alarms (Zone 2)
7.4.1 Alarm 2n01 : Interlock Chain Input 1 Fault
Meaning:
For JK laser products this input is allocated to the Interlock chain voltage feed.
Possible causes:
1. Interlock supply not turned on.
2. Loose connection.
3. Faulty interlock module.
There is no voltage supply to this interlock input.
Possible causes:
1. Interlock supply not turned on.
2. Loose connection.
3. Faulty interlock module.
Petitioners Canadian Solar Inc. and Canadian Solar (USA) Inc.
Ex. 1025, p. 76

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GSi JK300HP and is the answer not in the manual?

GSi JK300HP Specifications

General IconGeneral
BrandGSi
ModelJK300HP
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals