R
Intelligent Charging System Series
OWNER’S MANUAL
ON BOARD BATTERY CHARGERS
Models Amperage No. Of Banks Volts
16061
6 Amps 1 Bank 12
16102
6,6 Amps 2 Banks 12 or 24
16153
6,6,6 Amps 3 Banks 12 or 24 or 36
16202
10,10 Amps 2 Banks 12 or 24
IMPORTANT NOTICE
This manual contains important safety and operating instructions for the charger. Read
the entire manual before using. Also read all instructions and cautions for and on the
charger, batteries and equipment in the vicinity of the batteries.
SAVE THESE INSTRUCTIONS

Questions and Answers

  • N
    Nicole RobinsonAug 14, 2025
    What to do if Guest 16102 status GREEN LED is ON when the battery is not fully charged?
    • Y
      ytuckerAug 14, 2025
      If the Guest Battery Charger's green LED is on even when the battery isn't fully charged, it could be due to one of two reasons: 1. The 8-hour absorption stage timer has expired. Load test the batteries and replace if necessary. 2. One or more cells are defective or damaged. Turn off all DC equipment while charging.
  • J
    Jacob SmithAug 20, 2025
    What to do if Guest 16102 status RED LED is blinking 1 time?
    • J
      Jermaine BurkeAug 20, 2025
      If the Guest Battery Charger's red LED is blinking once, indicating no battery is present, here are a few potential causes and solutions: 1. The DC output fuse is open. Replace the DC output fuse with an equivalent size. 2. There are faulty or contaminated terminal connections. Clean, tighten, or repair all terminal connections. 3. One or more cells are defective or damaged. Load test the batteries and replace them if necessary. 4. There is reverse polarity across the battery. Replace the DC output fuse and correct the charger lead orientation. 5. No battery is present. Connect DC output connections to the battery.
  • C
    Crystal GayAug 27, 2025
    Why is Guest Battery Chemistry Indicator not identifying the correct battery chemistry?
    • J
      James GilbertAug 27, 2025
      If the Guest Battery Charger's battery chemistry indicator isn't correctly identifying the battery chemistry, it could be due to: 1. AC power was applied before battery chemistry selection was made. Disconnect both AC and DC power. Reconnect DC connections to the battery and follow section Setting Up the Battery Chemistry. 2. There was an interruption to both AC and DC battery power. Disconnect both AC and DC power. Reconnect DC connections to the battery and follow section Setting Up the Battery Chemistry.
  • H
    heidi05Sep 1, 2025
    What to do if Guest 16102 Battery Charger status RED LED is blinking 5 times?
    • D
      David SnyderSep 1, 2025
      If the Guest Battery Charger's red LED is blinking 5 times, it indicates a microprocessor check sum failure. Return charger to the Guest Service Dept.
  • J
    John RichNov 7, 2025
    What to do if Guest 16102 status RED LED is blinking 3 times?
    • S
      scottemilyNov 7, 2025
      If the Guest Battery Charger's red LED blinks 3 times, it indicates the 14-hour bulk timer has expired. This could be due to several reasons: 1. One or more defective or damaged cells. You should load test the batteries and replace them if necessary. 2. The charger has reduced its output voltage below the normal level because of a DC overload or a DC short. Remove the source of the overload or short. Disconnect the charger’s black (NEGATIVE) ring terminal from the battery. Reapply AC power, and the green LED only should now light. 3. On-board DC systems are drawing more current than the charger can replace. Turn off all DC equipment while charging. 4. Excessive ambient temperature has forced the charger to cut back output current to protect itself. Determine the cause of the excessiv...

Summary

IMPORTANT NOTICE

IMPORTANT SAFETY INSTRUCTIONS

WARNINGS

Important warnings about battery types and explosive gases during operation.

AC Connection and Grounding Precautions

DANGER and CAUTION notes regarding AC connection and grounding.

INTRODUCING THE CHARGER

Personal Safety Precautions

Adheres to personal safety precautions when installing or working with the chargers.

Preparing to Charge Precautions

Precautions to read before charging a battery with the charger.

INSTALLING THE CHARGER

Choosing a Mounting Location

Guidelines for selecting an appropriate mounting location for the charger.

Mounting the Charger

Instructions for mounting the charger using appropriate hardware.

Making the DC Connections

Instructions for making correct polarity DC connections to the battery.

Setting Up the Battery Chemistry

How to set the battery chemistry for each individual charger output.

Making AC Connection

Connect the AC plug into a GFCI protected receptacle.

Diagram 1 - 16061 Configuration

Diagram 2 - 16102 Dual Output Configuration

Diagram 3 - 16102 24 VDC Configuration

Diagram 4 - 16102 12 VDC Configuration

Diagram 5 - 16153 Triple Output Configuration

Diagram 6 - 16153 36 VDC Configuration

Diagram 7 - 16153 Multi-Voltage Configuration

Diagram 8 - 16153 Multi-Amp Configuration

Diagram 9 - 16153 12 VDC 18 A Configuration

Diagram 10 - 16202 Dual Output Configuration

Diagram 11 - 16202 24 VDC Configuration

Diagram 12 - 16202 12 VDC 20 A Configuration

OPERATING THE CHARGER

LED Function Chart

Describes the charging process for 6amp and 10amp models using LED indicators.

Battery Fault Indication

TROUBLESHOOTING

RED LED Blinking 3 times (14 hr. Bulk Timer Expired)

Troubleshooting steps for a charger with a blinking red LED (3 times) indicating timer expiration.

RED LED Blinking 5 times

Troubleshooting steps for a charger with a blinking red LED (5 times) indicating program memory issues.

RED LED Blinking 1 time (No Battery Present)

Troubleshooting steps for a charger with a blinking red LED (1 time) indicating no battery present.

Troubleshooting Common Issues

GREEN LED ON (Battery Not Fully Charged)

Troubleshooting for a green LED that stays on when the battery is not fully charged.

Incorrect Battery Chemistry Identification

Troubleshooting for incorrect battery chemistry identification by the indicator.

MAINTAINING THE CHARGER

SPECIFICATIONS

ADDITIONAL FEATURES

FCC Class A EMC Notice

LIMITED WARRANTY

Guest 16102 Specifications

General IconGeneral
BrandGuest
Model16102
CategoryBattery Charger
LanguageEnglish