COUPLE
 
The Couple commands can be used to remotely set the frequency 
coupling and amplitude coupling. 
SOURce[1|2]:FREQuency:COUPle:MODE 
 
Set the frequency coupling mode. 
SOURce[1|2]:FREQuency:COUPle:MODE 
{Off|Offset|Ratio} 
Disables frequency coupling. 
Set frequency coupling to offset mode. 
Sets frequency coupling to ratio mode. 
SOURce1:FREQuency:COUPle:MODE Offset 
Sets the frequency coupling mode to offset. 
SOURce[1|2]:FREQuency:COUPle:MODE? 
SOURce1:FREQuency:COUPle:MODE? 
Frequency coupling is turned off. 
SOURce[1|2]:FREQuency:COUPle:OFFSet  
 
Sets the offset frequency when the frequency 
coupling mode is set to offset. 
SOURce[1|2]:FREQuency:COUPle:OFFSet {frequency} 
SOURce1:FREQuency:COUPle:OFFSet 2khz 
Sets the offset frequency to 2kHz (the frequency of 
CH2 minus CH1 is 2kHz). 
SOURce[1|2]:FREQuency:COUPle:OFFSet? 
SOURce1:FREQuency:COUPle:OFFSet?