PSU Series User Manual 
104 
Auto Calibration 
Parallel Control 
This function performs offset calibration for 
parallel control. There must be a short between 
each unit before starting the calibration. See page 
77 for details. 
0 = Disable, 1 = Enable, 2 = 
Execute Parallel Calibration and 
set to Enable 
Measurement 
Average Setting 
Determines the level of smoothing for the average 
setting.  
0 = Low, 1 = Middle, 2 = High 
Alarm Recovery 
and Output 
Status 
Set the output status when OHP, FAN and AC-Fail 
alarm be cleared. 
0 = Safe Mode, 1 = Force Mode 
When the front panel is locked, the Lock Mode 
function determines the behavior of the Output 
key. 
0: Lock Panel, Allow Output OFF            
1: Lock Panel, Allow Output 
ON/OFF 
Interface Configuration Settings 
USB / GPIB Settings 
 
Show Front Panel 
USB Status 
Displays the front panel USB-A port state. This 
setting is not configurable. 
0 = None, 1 = Mass Storage  
Show Rear Panel 
USB Status 
Displays the rear panel USB-B port state. This 
setting is not configurable. 
0 = None, 1 = Linking to PC