PSU Series User Manual 
100 
External Output Control 
Function 
Trigger Input and Output Configuration Settings 
Trigger Input Pulse 
Width 
0~60ms. 0 = trigger controlled by 
trigger level. 
0 = None 
1 = Output ON/OFF (refer to F103) 
2 =  Setting (refer to F104 & F105) 
3 = Memory (refer to F106) 
Output State When 
Receiving Trigger 
Apply Voltage Setting on 
Trigger 
0 ~ rated voltage (only applicable 
when F102 =2) 
Apply Current Setting on 
Trigger 
0 ~ rated current (only applicable 
when F102 =2) 
Trigger Output Pulse 
Width 
0 ~ 60ms. 0 = trigger output is set to 
the active level, not pulse width.  
0 = LOW, 1 = HIGH (If F120 = 0) 
0 = None 
1 = Switching the output on or off 
2 = Changing a setting 
3 = Recalling a memory 
Special Function Settings* 
Power on configuration settings only can be set during 
power up. Under normal operation they only can be 
viewed.