PSU Series User Manual 
206 
*1
 Minimum voltage is guaranteed to maximum 0.2% of the rated output voltage. 
*2
 Minimum current is guaranteed to maximum 0.4% of the rated output current. 
*3
 At 85 ~ 132Vac or 170 ~ 265Vac, constant load. 
*4
 From No-load to Full-load, constant input voltage. Measured at the sensing point in 
  Remote Sense. 
*5
 Measure with JEITA RC-9131B (1:1) probe 
*6
 Measurement frequency bandwidth is 10Hz to 20MHz. 
*7
 Measurement frequency bandwidth is 5Hz to 1MHz. 
*8
 From 10% to 90% of rated output voltage, with rated resistive load. 
*9
 From 90% to 10% of rated output voltage, with rated resistive load. 
*10
 Time for output voltage to recover within 0.5% of its rated output for a load change from 
  0 to 90% of its rated output current. Voltage set point from 10% to 100% of rated 
  output. 
*11
 For load voltage change, equal to the unit voltage rating, constant input voltage. 
*12
 For 6V~20V model the ripple is measured at 2V ~ rated output voltage and full output 
  current. For other models, the ripple is measured at 10 ~ 100% output voltage and full 
  output current. 
*13
 At rated output power. 
*14
 If install the front panel filter kit, the temperature is guaranteed to 40˚C.