Page 61
2. Operate the instrument as normal.
See the Serial Operation chapter
for details.
Page 77
Wire Shielding
and Load line
impedance
To help to minimize the oscillation due to the
inductance and capacitance of the load cables, use
an electrolytic capacitor in parallel with the load
terminals.
To minimize the effect of load line impedance use
twisted wire pairing.
PSU Load
s
s
Twisted pair
Capacitor
Shield the sense wires and connect
the shield to the chassis ground.
Twisted pair