PERFORMANCE ADJUSTMENT
31
6. Turn the current coarse
and fine knobs fully
clockwise to the
maximum positions.
&855(17
&&
&2$56(),1(
7. Turn the current coarse
and fine knobs to the
centered position
&855(17
&&
&2$56(),1(
8. Adjust VR303 so that the multimeter displays
the following values.
SPS-1820 20.10A
SPS-3610 10.10A
SPS-606 6.10A
SPS-2145 15.1A
SPS-1230 30.1A
9. Adjust VR2 so that the current value of the
ammeter display matches the current shown in
the multimeter.
10. Press the AMPS key to set the
current range to low.
11. Adjust VR310 so that the multimeter displays
the following values. (half of the rating current)
SPS-1820 10.0A
SPS-3610 5.0A