120
Ste
p
Command
1. Enter system view.
system-view
2. Enter monitor link group view.
monitor-link group group-id
3. Configure member ports for the monitor link group.
port interface-type interface-number { uplink |
downlink }
In interface view
To configure member ports for a monitor link group in interface view:
Ste
p
Command
1. Enter system view.
system-view
2. Enter Layer 2 Ethernet interface view or Layer 2
aggregate interface view.
interface interface-type interface-number
3. Configure the current interface as a member of a
monitor link group.
port monitor-link group group-id { uplink |
downlink }
Displaying and maintaining Monitor Link
Task Command
Remarks
Display monitor link group
information.
display monitor-link group { group-id | all } [ |
{ begin | exclude | include } regular-expression ]
Available in any view
Monitor Link configuration example
Network requirements
As shown in Figure 27, Device C is a smart link device, and Device A, Device B, and Device D are
associated devices. Traffic of VLANs 1 through 30 on Device C is dual-uplinked to Device A through a
smart link group.
Implement dual uplink backup on Device C, and make sure that when the link between Device A and
Device B (or Device D) fails, Device C can sense the link fault and perform uplink switchover in the smart
link group.
For more information about Smart Link, see "Configuring Smart Link."