9
Ste
Command
Remarks
1. Enter system view.
system-view N/A
2. Configure the Ethernet OAM
handshake packet
transmission interval.
oam timer hello interval
Optional.
1000 millisecond by default.
3. Configure the Ethernet OAM
connection timeout timer.
oam timer keepalive interval
Optional.
5000 milliseconds by default.
Configuring link monitoring
After Ethernet OAM connections are established, the link monitoring periods and thresholds configured
in this section take effect on all Ethernet ports automatically.
Configuring errored symbol event detection
Ste
Command
Remarks
1. Enter system view.
system-view N/A
2. Configure the errored
symbol event detection
interval.
oam errored-symbol period period-value
Optional.
1 second by default.
3. Configure the errored
symbol event triggering
threshold.
oam errored-symbol threshold
threshold-value
Optional.
1 by default.
Configuring errored frame event detection
Ste
Command
Remarks
1. Enter system view.
system-view N/A
2. Configure the errored frame
event detection interval.
oam errored-frame period
period-value
Optional.
1 second by default.
3. Configure the errored frame
event triggering threshold.
oam errored-frame threshold
threshold-value
Optional.
1 by default.
Configuring errored frame period event detection
Ste
Command
Remarks
1. Enter system view.
system-view N/A
2. Configure the errored
frame period event
detection period.
oam errored-frame-period period
period-value
Optional.