126
If the consecutive failures reach the specified threshold, the NQA module tells the track module that
the tracked object malfunctions. Then the track module sets the track entry to the Negative state.
If the specified threshold is not reached, the NQA module tells the track module that the tracked
object functions normally. The track module then sets the track entry to the Positive state.
For more information about NQA, see Network Management and Monitoring Configuration Guide.
To associate track with NQA:
Ste
p
Command
Remarks
1. Enter system view. system-view N/A
2. Create a track entry,
associate it with an NQA
reaction entry, and specify the
delay time for the track
module to notify the
associated application
module when the track entry
status changes.
track track-entry-number nqa entry
admin-name operation-tag reaction
item-number [ delay { negative
negative-time | positive
positive-time } * ]
No track entry is created by
default.
NOTE:
If the specified NQA test group or the reaction entry in the track entry does not exist, the status of the trac
k
entry is Invalid.
Associating track with interface management
The interface management module monitors the physical status or network-layer protocol status of the
interface. The interface management module functions as follows when it is associated with a track entry:
When the physical or network-layer protocol status of the interface changes to up, the interface
management module informs the track module of the change and the track module sets the track
entry to Positive.
When the physical or network-layer protocol status of the interface changes to down, the interface
management module informs the track module of the change and the track module sets the track
entry to Negative.
To associate track with interface management:
Ste
p
Command
Remarks
1. Enter system view.
system-view N/A