EasyManua.ls Logo

H3C S5120-EI Series - Page 59

H3C S5120-EI Series
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50
Interface GigabitEthernet1/0/49
DLDP port state : advertisement
DLDP link state : up
The neighbor number of the port is 1.
Neighbor mac address : 0023-8956-3600
Neighbor port index : 59
Neighbor state : two way
Neighbor aged time : 11
Interface GigabitEthernet1/0/50
DLDP port state : advertisement
DLDP link state : up
The neighbor number of the port is 1.
Neighbor mac address : 0023-8956-3600
Neighbor port index : 60
Neighbor state : two way
Neighbor aged time : 12
The output shows that both GigabitEthernet 1/0/49 and GigabitEthernet 1/0/50 are in
Advertisement state, which means both links are bidirectional.
# Enable system information monitoring on Device A, and enable the display of log and trap
information.
[DeviceA] quit
<DeviceA> terminal monitor
<DeviceA> terminal logging
<DeviceA> terminal trapping
The following log and trap information is displayed on Device A:
<DeviceA>
#Jan 18 18:10:38:481 2013 DeviceA DLDP/1/TrapOfUnidirectional: -Slot=1; Trap
1.3.6.1.4.1.25506.2.43.2.1.1<hh3cDLDPUnidirectionalPort> : DLDP detects a
unidirectional link in port 17825792.
%Jan 18 18:10:38:481 2013 DeviceA DLDP/3/DLDP_UNIDIRECTION_MANUAL: -Slot=1; DLDP
detects a unidirectional link on port GigabitEthernet1/0/49. The transceiver has
malfunction in the Tx direction or cross-connected links exist between the local device
and its neighbor. The shutdown mode is MANUAL. The port needs to be shut down by the
user.
#Jan 18 18:10:38:618 2013 DeviceA DLDP/1/TrapOfUnidirectional: -Slot=1; Trap
1.3.6.1.4.1.25506.2.43.2.1.1<hh3cDLDPUnidirectionalPort> : DLDP detects a
unidirectional link in port 17825793.
%Jan 18 18:10:38:618 2013 DeviceA DLDP/3/DLDP_UNIDIRECTION_MANUAL: -Slot=1; DLDP
detects a unidirectional link on port GigabitEthernet1/0/50. The transceiver has
malfunction in the Tx direction or cross-connected links exist between the local device
and its neighbor. The shutdown mode is MANUAL. The port needs to be shut down by the
user.
The output shows that DLDP has detected a unidirectional link on both GigabitEthernet 1/0/49
and GigabitEthernet 1/0/50, and is asking you to shut down the faulty ports manually.
After you shut down GigabitEthernet 1/0/49 and GigabitEthernet 1/0/50, the following log
information is displayed:

Table of Contents

Other manuals for H3C S5120-EI Series

Related product manuals