Mounting the firewall on a workbench
IMPORTANT:
Ensure good ventilation and a minimum clearance of 100 mm (3.94 in) around the chassis for
heat dissipation.
Avoid placing heavy objects on the firewall.
To stack firewalls, make sure a minimum vertical distance of 15 mm (0.59 in) is available between
two adjacent firewalls.
If a standard 19-inch rack is not available, you can place the firewall on a workbench.
To mount the firewall on a workbench:
1. Verify that the workbench is sturdy and reliably grounded.
2. Place the firewall upside down on the workbench and clean the four round holes in the chassis
bottom with a dry cloth.
3. Attach the four rubber feet to the round holes in the chassis bottom.
4. Place the firewall with upside up on the workbench.
Figure 4 Mounting the firewall on a workbench
Installing the firewall in a standard 19-inch rack
WARNING!
To avoid bodily injury and device damage, use a minimum of two persons to rack-mount the firewall.

Table of Contents

Other manuals for H3C SecPath F10 0 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C SecPath F10 0 Series and is the answer not in the manual?

H3C SecPath F10 0 Series Specifications

General IconGeneral
BrandH3C
ModelSecPath F10 0 Series
CategoryNetwork Hardware
LanguageEnglish

Related product manuals