8
Item
Requirements
Result
Separate the protection ground of the firewall from
the grounding device or lightning protection
grounding device as far as possible.
Keep the firewall far away from radio stations, radar
and high-frequency devices working in high current.
Use electromagnetic shielding when necessary.
Lightning
protection
The grounding cable of the chassis is reliably
grounded.
The grounding terminal of the AC power receptacle is
reliably grounded.
(Optional.) A power lightning arrester is installed.
Electricity safety
Equip a UPS.
Locate the power switch in the equipment room. In
case of emergency during operation, switch off the
power switch.
Rack-mounting
requirements
Make sure the cabinet is equipped with a good
ventilation system.
The rack is sturdy enough to support the weight of the
firewall and installation accessories.
The size of the rack is appropriate for the firewall.
The front and rear of the rack are a minimum of 0.8 m
(31.50 in) away from walls or other devices.
Safety
precautions
The firewall is far away from any moist area and heat source.
The emergency power switch in the equipment room is located.
Tools and
accessories
Installation accessories supplied with the firewall
User-supplied tools
Reference
Documents shipped with the firewall
Online documents

Table of Contents

Other manuals for H3C SecPath F1000-AI-5 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the H3C SecPath F1000-AI-5 Series and is the answer not in the manual?

H3C SecPath F1000-AI-5 Series Specifications

General IconGeneral
BrandH3C
ModelSecPath F1000-AI-5 Series
CategoryFirewall
LanguageEnglish

Related product manuals