Lubrication Verification
1
Run the spindle run-in program.
Examine the sight glass, make sure the correct number of drops are fall through the sight glass.
Examine the fittings [1,2] on top of the oil pump tank.
The oil collects on top of the oil pump tank [3] either behind or in front of the sight glass bracket,
underneath the leaking fitting.
Tighten any leaking fittings.
2
Go to the Maintenance tab.
Press [F2] to cycle an axis lubrication test.
Inspect the gauge on the grease lubrication system. Make sure it holds pressure.