11
Test Safety Features
Turn the (Run / Set-up) key switch to the Set-up mode
Test Memory Lock switch by verifying that in the ON position changes cannot be made to settings or
programs.
Press [MDI] and type M03 S500;
Open door. Press [CYCLE START] the spindle should not start.
Close door. Press [CYCLE START] the spindle should start.
Verify door cannot be opened when spindle is running
Verify door can open when spindle is off.
Verify that a window latch is installed on each side window and test that they hold the windows up in
their lock positions
Verify that the windows lock close in the down position.
For 110V machines conduct a GFCI Test with a 110V GFCI tester at the plug point on the side of the
control
For 240V machines conduct a GFCI test with a 240V GFCI tester at the coolant pump connector