EasyManuals Logo

Hach AS950 User Manual

Hach AS950
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
Table of Contents
Product overview....................................................................................................... 3
User interface and navigation.............................................................................. 3
Keypad and display description................................................................................... 3
Main menu overview.................................................................................................... 4
Operation....................................................................................................................... 5
Configuration............................................................................................................... 5
Configure the general settings.............................................................................. 5
Configure the hardware settings........................................................................... 6
Configure the sensors................................................................................... 6
Configure the AUX I/O port......................................................................... 10
Configure data logging....................................................................................... 11
Select and configure the alarms......................................................................... 12
Sampling program configuration......................................................................... 13
Select the type of program.......................................................................... 13
Enter the bottle and tubing information....................................................... 14
Select the sample pacing............................................................................ 14
Select the sample volume........................................................................... 15
Select the sample distribution—multiple bottles.......................................... 16
Select when the sampling program starts................................................... 19
Select when the program stops................................................................... 20
Configure cascade sampling (optional).............................................................. 20
Configure synchronized sampling (optional)...................................................... 21
Calibration.................................................................................................................. 21
Volume calibration.............................................................................................. 21
Calibrate the sample volume—liquid detector enabled............................... 22
Adjust the sample volume calibration (optional).......................................... 22
Calibrate the sample volume—liquid detector disabled.............................. 23
Verify the sample volume............................................................................ 23
Calibrate the sensors.......................................................................................... 23
Calibrate the cabinet temperature—AWRS sampler.......................................... 24
Start or stop the program........................................................................................... 24
Show data and alarms............................................................................................... 24
Show the program status.................................................................................... 24
Show the sample history.................................................................................... 26
Show the measurement data.............................................................................. 26
Show the event log............................................................................................. 26
Show the alarm log............................................................................................. 27
Show system information........................................................................................... 27
Save logs and settings to a USB drive...................................................................... 27
Use FSDATA Desktop (optional)............................................................................... 28
Manual operation....................................................................................................... 28
Collect a grab sample......................................................................................... 28
Move the distributor arm..................................................................................... 28
Start or stop the pump........................................................................................ 29
Troubleshooting....................................................................................................... 29
Do a diagnostic test................................................................................................... 29
1

Other manuals for Hach AS950

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hach AS950 and is the answer not in the manual?

Hach AS950 Specifications

General IconGeneral
Sample FrequencyProgrammable
TypePortable
Sampling MethodVacuum Pump
Temperature ControlRefrigerated
Bottle Configuration24 x 1L bottles
Power Supply12V DC
CommunicationRS-232
Sampler TypePortable or Stationary
Vertical Lift8.2 m
Enclosure RatingIP67
Number of SamplesUp to 999
Storage Capacity24 samples
Bottle Options1L