Read the entire manual, pay attention to warnings and cautions. Use equipment as specified.
Defines hazard symbols like DANGER, WARNING, CAUTION, NOTICE for safety.
Details safety precautions for electrical connections, power, and general handling.
States that only authorized personnel should service the analyzer.
Lists detailed technical specifications for the analyzer's operating conditions and requirements.
Provides operating conditions, EMC requirements, safety rating, enclosure ratings, and power supply.
Lists specifications for the K1200 sensor, including measurement ranges, accuracy, and weight.
Provides specifications for TC sensors, including membranes, measurement ranges, and accuracy.
A step-by-step checklist to ensure proper completion of the installation process.
Provides instructions for mounting the instrument on walls or pipes.
Detailed steps for attaching the instrument to a wall using a bracket.
Detailed steps for attaching the instrument to a pipe using a mounting bracket.
Instructions for installing the instrument as a panel mount.
Provides steps for mounting the panel instrument into a panel opening.
Instructions for connecting the instrument to the mains power supply.
Details connecting low voltage power supply (10-30 VDC) using a BINDER connector.
Details connecting high voltage power supply (100-240 VAC) and user-supplied cable specifications.
Instructions for connecting sensors and other electronic components to the boards.
Provides instructions for installing sensors into the instrument.
Details the requirements and setup for the TC sensor purge gas system.
Step-by-step instructions for inserting the sensor into the flow chamber or socket.
Instructions for safely removing the sensor from the sample line.
Details the portable calibration device for the K1200 sensor and its usage.
Explains measurement configuration for TC and K1200 sensors.
Details measurement configuration options for TC sensors (medium, gas unit, thermal cutoff).
Manual calibration procedures for K1200 sensors (zero, high level).
Step-by-step guide for performing manual calibration of the sensor.
Procedure for performing zero calibration using N2 gas.
Procedure for 100% humid air calibration for high range sensors.
Procedure for high level adjustment using a known gas concentration.
Procedures for calibrating TC gas sensors, including modifying parameters and checking results.
Procedure for calibrating the barometric pressure sensor.
Methods for calibrating the external pressure sensor (two-point, one-point).
Procedure for calibrating the analog output current or voltage.
Configuration for RS-485 simple mode to output data to external devices.
Introduction to PROFIBUS-DP communication.
Instructions for installing the PROFIBUS-DP module and configuring the instrument.
Overview of HTTP/TCP-IP option for accessing instrument data via a web page.
Details on enabling the web server link and accessing the web page.
Managing user access rights and levels for instrument functions.
Configuring security parameters like access rights and session time.
Adding, editing, or deleting registered users and their access levels.
Checking sensor status, calibration timer, and service timer.
Performing general or zero diagnostics for the K1200 sensor.
Checking TC sensor performance for gas and temperature measurements.
General information on instrument maintenance procedures.
Procedures for replacing the sensor spot on the K1200 sensor.
Step-by-step instructions for removing the old K1200 sensor spot.
Step-by-step instructions for installing a new K1200 sensor spot.
General maintenance procedures for TC sensors.
Step-by-step instructions for replacing the TC sensor membrane.
Guidance on interpreting instrument messages and troubleshooting abnormal conditions.
A table listing events, their descriptions, and bit mask values.