EasyManuals Logo

Hach Polymetron Series User Manual

Hach Polymetron Series
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #451 background imageLoading...
Page #451 background image
 5  DIAG/TEST )/ (  )(

SENSOR SIGNALS ) 
(
      
 /.
SENSOR DAYS )  (     .
RESET SENSOR DAYS )  
 (
       .
 
              
     .       MENU
)(   Sensor Diag )  (] Select Sensor) [ 
( Error List )  .(      6.
 6     

MEAS TOO HIGH
)  
(
 <
2.000.000  / 
1.000.000    
20.000   
     
 .
MEAS TOO LOW
)  
(
  > 0  /
 0     0  

     
 .
ZERO TOO LOW
)  
(
  >
500.000 
      
    
     
 .   
 .
ZERO TOO LOW
)  
(
  >
500.000 
 6      )(

TEMP TOO HIGH
)  
(
   < 130 

     
   .  
    450.
TEMP TOO LOW
)  
(
  
– >10  
ADC FAILURE
)  
(
         
   . 
.
SENSOR
MISSING )
 (
       
     
    .
SENS OUT
RANGE )
  (
    
   
)0.01 0.05 :100 
/ 0.5 :1000 
/ 1 :2000 
/ 5 :10.000 
/ 10 :200.000 
/(
     
 .
   
       .    
   .       MENU )( 
 Sensor Diag )  (] Select Sensor) [  (
Warning List )  .(      7.
 7     

ZERO TOO LOW )
  (
  <
300.000 
      
    
     
 .   
 .
ZERO TOO LOW )
  (
  
– >300.000 
451



Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hach Polymetron Series and is the answer not in the manual?

Hach Polymetron Series Specifications

General IconGeneral
BrandHach
ModelPolymetron Series
CategoryAccessories
LanguageEnglish

Related product manuals