DOC023.53.90050
TSS Portable handheld
measurement instrument for turbidity/solids
User Manual
01/2018, Edition 6

Table of Contents

Other manuals for Hach TSS Portable

Questions and Answers

  • J
    jennifer28Aug 15, 2025
    What to do if Hach Measuring Instruments shows a calibration error?
    • S
      Samantha WarrenAug 15, 2025
      A calibration error on the Hach Measuring Instruments means there is no calibration available, or the calibration points are set incorrectly (upper and lower calibration points transposed). Recalibration is required. Note that a 1-point default calibration of DS curves may not be sufficiently precise for the measuring medium.
  • M
    Mary HamiltonAug 18, 2025
    How to fix 'Battery is empty' error on Hach TSS Portable?
    • M
      Michelle BruceAug 18, 2025
      If the Hach Measuring Instruments indicates that the battery is empty, it's likely that the battery hasn't been charged. Fully charge the battery to resolve this issue.
  • T
    Troy LawrenceAug 21, 2025
    Why Hach TSS Portable is not communicating with the probe?
    • J
      Joseph Wells MDAug 22, 2025
      If your Hach Measuring Instruments is having trouble communicating with the probe, the probe might not be properly connected. Ensure the probe is securely plugged in and that the connection is correct. Verify that the probe number is also correct.
  • P
    phannaAug 26, 2025
    What to do if Hach TSS Portable displays a probe error?
    • L
      lekaylaAug 26, 2025
      If the Hach Measuring Instruments displays a probe error, it indicates a technical issue with the probe. Try switching the instrument off and then back on again. If the message persists, the probe may need to be sent for repair.
  • S
    steve12Aug 28, 2025
    What to do if Hach Measuring Instruments shows an incorrect probe error?
    • D
      Derek TurnerAug 28, 2025
      If the Hach Measuring Instruments indicates an incorrect probe, it means the probe has been replaced but not re-registered or correctly registered on the instrument. Connect the correct probe and use code 390 to release the DS curve for the new probe, then recalibrate.
  • T
    Tanya SmithSep 1, 2025
    What does overflow area mean on Hach TSS Portable?
    • D
      David BlairSep 1, 2025
      If the Hach Measuring Instruments displays an overflow area error, it means the concentration is too high. The probe might be measuring in an unsuitable medium, or it may be necessary to recalibrate.
  • J
    John MartinSep 4, 2025
    What causes offset error on Hach TSS Portable Measuring Instruments?
    • J
      jessica79Sep 4, 2025
      An offset error on the Hach Measuring Instruments indicates that the calibration point was set incorrectly, specifically too close to the zero point. Recalibration is required to correct this.
  • M
    Mary DavisSep 7, 2025
    How to correct time/date error on Hach Measuring Instruments?
    • W
      williamtaylorSep 8, 2025
      If the Hach Measuring Instruments displays a time/date error, it means the time or date is implausible. Try switching the instrument off and then back on again. Check the time and date settings, and if required, change the clock batteries.
  • L
    lauralaraSep 12, 2025
    How to fix EEPROM error on Hach Measuring Instruments?
    • G
      gguerreroSep 12, 2025
      To solve EEPROM error on Hach Measuring Instruments, switch the instrument off and then back on again.

Summary

General Information

Safety Information

Covers crucial safety protocols, hazard notices, and precautionary labels for instrument operation.

Installation

Start Up

Calibration and Measurement Points

Details the necessity of calibration for solids measurement and defines calibration curves and points.

Operation

Calibration Procedures

Covers important notes, 1-point/multi-point calibration, value correction, deletion, and resetting to default.

Measurement Operations

Details how to select calibration curves, start, interrupt, resume, and stop measurements.

Troubleshooting

Error and Informative Messages

Lists common error messages, their causes, and recommended actions, along with informative messages.

Hach TSS Portable Specifications

General IconGeneral
Operating Temperature0 to 50 °C
Storage Temperature-20 to 60 °C
DetectorSilicon photodiode
Battery LifeApproximately 1000 measurements
Light SourceLED
Power Supply4 AA batteries
Weight400 g
MethodNephelometric