Hach TL2350 - User Manual

Hach TL2350
176 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DOC022.97.80535
TL2350
07/2016, Edition 2
Basic User Manual
Manuel d'utilisation de base
Manual básico del usuario
Manual Básico do Usuário
基本用户手册
基本取扱説明書
기본 사용 설명서
คู่มือผู้ใช้เบื้องต้น

Table of Contents

Questions and Answers

  • W
    wernerjamesAug 20, 2025
    Why does my Hach Measuring Instruments say 'Next calibration is due'?
    • B
      Brenda BeanAug 20, 2025
      If the Hach Measuring Instruments displays 'Next calibration is due!', calibrate the instrument.
  • C
    Charles RobertsAug 22, 2025
    What does 'Next verification is due' mean on Hach Measuring Instruments?
    • U
      ufieldsAug 22, 2025
      If the Hach Measuring Instruments displays 'Next verification is due!', perform a calibration verification.
  • H
    Hector HughesAug 25, 2025
    What does 'The calibration range is exceeded' mean on Hach Measuring Instruments?
    • P
      Peter JonesAug 25, 2025
      If the Hach Measuring Instruments displays 'The calibration range is exceeded', it means the measured turbidity is higher than the instrument's calibration range. You should select a calibration curve that matches the full measurement range.
  • T
    Theodore WatersAug 26, 2025
    What to do if Hach Measuring Instruments shows a hardware error?
    • J
      Justin ChambersAug 26, 2025
      If the Hach Measuring Instruments displays a hardware or instrument error, power it off, wait 20 seconds, and then power it back on.
  • M
    mnortonAug 28, 2025
    How to fix 'Cannot write to USB memory' on Hach Measuring Instruments?
    • N
      Natasha SpencerAug 28, 2025
      If the Hach Measuring Instruments displays 'Cannot write to USB memory', connect a USB flash drive to the instrument, ensuring the file system "FAT32" is installed. Power the instrument off, wait 20 seconds, then power it back on. Check the USB flash drive for available space, and repeat the power cycle before reconnecting the USB flash drive to the instrument.
  • E
    efitzgeraldAug 30, 2025
    What to do if Hach Measuring Instruments says USB memory is not connected?
    • M
      Michelle ReidAug 30, 2025
      To resolve the 'USB memory is not connected' error on the Hach Measuring Instruments, connect a USB flash drive to the instrument, ensuring it uses the FAT32 file system. Power the instrument off, wait 20 seconds, then power it back on. Reconnect the USB flash drive and restart the instrument update procedure.
  • J
    Jay JenkinsAug 31, 2025
    How to fix Hach Measuring Instruments instrument update file is missing?
    • D
      David MorenoAug 31, 2025
      If the Hach Measuring Instruments displays 'Instrument update file is missing', remove the instrument update files from the USB flash drive. Save the instrument update files again to the USB flash drive. Connect the USB flash drive to the instrument. Start the instrument update procedure again.
  • J
    Jeffrey HarrisSep 2, 2025
    How to fix Hach Measuring Instruments copy from USB memory failed?
    • Z
      znguyenSep 3, 2025
      If the Hach Measuring Instruments displays 'Copy from USB Memory failed', remove large files from the USB flash drive to free up space. Restart the instrument update procedure. Remove the update files from the USB drive, save them again, connect the drive, and try the update again.
  • T
    Tamara JonesSep 4, 2025
    What to do if Hach Measuring Instruments says the standard is not stable?
    • M
      Michael MendozaSep 4, 2025
      If the Hach Measuring Instruments displays 'The standard is not stable', use the correct calibration standards and invert the standard until no bubbles or large particles are visible.
  • J
    jasonjohnsonSep 6, 2025
    Why does Hach Measuring Instruments say the standard value is too high?
    • S
      sawyerrobinSep 6, 2025
      If the Hach Measuring Instruments displays 'The standard value is too high', the wrong calibration standard is in the vial compartment or the standard has expired. Ensure the correct, unexpired calibration standard is in the vial compartment.

Summary

Specifications

Accuracy and Repeatability

Provides accuracy and repeatability specifications for various measurement modes.

Safety Information

Hazard Information Definitions

Explains the meaning of DANGER, WARNING, CAUTION, and NOTICE hazard symbols.

Precautionary Label Interpretation

Instructs users to read labels and explains symbol meanings on the instrument.

Product Overview

Product Components Identification

Lists and identifies the physical components of the turbidimeter.

Installation

Installation Guidelines

Provides recommendations for optimal instrument installation location and environment.

User Interface and Navigation

Startup

Startup Procedure Overview

Explains the initial steps to power on and start the instrument.

Operation

Instrument Settings Configuration

Guides users through configuring settings like location, date/time, and security.

Measurement Settings Configuration

Explains how to set reading modes, units, and other measurement parameters.

Operator ID Management

Instructions for adding, editing, and deleting operator IDs, passwords, and security levels.

Sample ID Management

Steps for adding sample IDs manually or importing them from a file.

Turbidimeter Calibration Procedure

Procedure for calibrating the turbidimeter using StablCal standards.

Calibration Settings Configuration

Details on how to configure calibration settings before performing calibration.

StablCal Calibration Step-by-Step

Step-by-step guide for performing a StablCal calibration.

Verification Procedure

Procedure for verifying instrument calibration using standards.

Turbidity Measurement

General Measurement Notes

Key considerations for accurate and repeatable turbidity measurements.

Turbidity Measurement Step-by-Step

Step-by-step process for performing a turbidity measurement.

Data Management

Maintenance

Lamp Replacement Safety

Safety precautions and notes for replacing the instrument's lamp.

Troubleshooting

Startup Issues

Common startup problems and their solutions.

Hach TL2350 Specifications

General IconGeneral
ModelTL2350
Measurement Range0 to 1000 NTU
Light SourceLED
Operating Temperature0 to 50 °C (32 to 122 °F)
Warranty1 year
CategoryTurbidimeter
Resolution0.01 NTU
Accuracy±2% of reading
Measurement MethodNephelometric
Power Supply4 AA batteries
DisplayLCD
Response TimeLess than 6 seconds

Related product manuals