4 31-5000496 Rev. 1
Spécifications
Intérieur USYF09UCDWA USYF12UCDWA USYF18UCDWA
Capacité de climatisation nominale Btu/h 9,000 12,000 15,000
Capacité de chau󰀨age nominale Btu/h 10,000 13,000 18,000
Tension, Cycle, Phase V/Hz/- 208-230/60/1
Débit d’air (Turbo/Haut/Moy/Bas/Silence) pi3/min 264/235/205/176/147 294/264/235/205/176 341/311/282/252/223
Niv. sonore int. (Turbo/Haut/Moy/Bas/Silence) dB 40/32/25/20 42/34/26/21 46/37/33/28
Dimensions du châssis : H x L x P po (mm) 23.6/27.5/8.7(600/700/220)
Poids (Exp./Net) – lb (kg) 36/40 (16.5/18.5)
Liquide/Aspiration D.E. po 1/4 3/8 1/4 3/8 1/4 1/2
Tuyau d'évacuation D.E. po (mm) φ 5/8 (16.5)
Outils nécessaires pour l’installation
• Fil torsadé 14/4 AWG
Clé 5/8 (16 mm), 7/8 (22 mm), 1 po (25 mm) ou
réglable
• Frigorigène R-410A*
• Ruban adhésif
• Bride de câble de conduit 1/2 po*
• Tuyauterie en cuivre
• Tournevis cruciforme no 2
• Perceuse
• Outil à évaser pour R-410A
• Clé hexagonale
• Scie-cloche 2 1/4 po
• Isolant*
• Balance pour réfrigérant
• Niveau
• Ensemble de manomètre de pression
• Ruban à mesurer
• Microvacuomètre
Adaptateur « mini-split » (5/16 po F à 1/4 po M)
• Azote*
• Coupe-tuyau
• Tuyau PVC (facultatif)
• Couteau utilitaire
• Alésoir
• Bride de tuyau (L.S.) avec vis
• Scellant, non expansif (pour trou de tuyauterie)
Solution d’eau savonneuse* ou détecteur de
fuite de gaz
• Localisateur de montants
• Clé dynamométrique
• Pompe à vide
• Pinces à dénuder
Tous les outils manuels ou électriques pour
CVC ainsi que les appareils de mesure et de
test.
*consommables
Instructions d’installation