PRECAUTION
Execute  proper  grounding.  Do  not  connect  the  earth  wire  to  a  gas  pipe,  water  pipe, 
lightening rod,  or  a  telephone  ground  wire.
Improper  placement  of  earth  wires  can  result  in  electric  shock.
An  electric  leakage  breaker  must  be  installed,  otherwise  electric  shock  or  other  accidents
would  occur.
After  completion  of  the  installation,  the  air  conditioner  shall  be  electrified  to  check  for
electric  leakage.
Preparation  for  installation
Installation  Tools
1.    Screw  Driver  (flat  head,  wabbler,  triangle)
2.    Steel  Saw
3.    60mm  Drill
4.    Inner  Hexagon  Spanner
5.    Shifting  Spanner
6.    Spanner 
7.    Pipe  Cutter
8.    Pipe  Expander
9.    Knives
10.  Clippers
11.  Leakage  Checker  or  Soap  Liquid
12.  Measuring  Tape
13.  Scraper  or  File
14.  Refrigeration  Oil
Self-contained Accessories
Electrical  Requirements
    Power  supply  voltage:  Single  Phase  1PH, 220-230V~, 50Hz.
    A  specialized  power  supply  wire,  which  shall  be  installed  by  a  competent  person  as  per  the 
    rules  of  the  national  standard.
    Power  supply  must  be  grounded  effectively.
    An  electric  leakage  breaker  shall  be  installed.
    Layout  of  power  supply  wiring  shall  be  Y  connection.  If  the  power  supply  wire  is  damaged,  it
    must  be  replaced  by  the  manufacturer  or  its  service  center  or  professional  person  (the  power
    supply  wire  shall  be  self-contained).
    For  connection  of  the  power  supply  plug,  L  shall  be  connected  with  the  live  wire,  N  shall  be
    connected  with  netural  line,       shall  be  connected  with  earth  wire.
    Power supply  wire  parameters:H05RN-F,3 G(1.0-1.5)mm ;
    Signal  wire  parameters:H05RN-F,2   (0.75-1.5)mm . (User  shall  self-provide  signal wire )
Name  of
Parts
No. A B C D E F
Non-adhesive
Tape
Adhesive
tape
Connecting
Hose
Gypsum
powder
Drain  hoseHeat
insulation
material
2
2
X
Note:The singnal wire and connection wire should be provided for oneself.
          The singnal wire must be shielded wire
WARNING
BE  SURE  TO  READ  THESE  INSTRUCTIONS  CAREFULLY  BEFORE  BEGINNING  INSTALLATION.  FAILURE TO
FOLLOW  THESE  INSTRUCTIONS  COULD  CAUSE  SERIOUS  INJURY  OR  DEATH,  EQUIPMENT  MALFUNCTION
AND/OR  PROPERTY  DAMAGE.
BE  SURE  TO  READ  INSTALLATION  MANUAL  FOR  INDOOR  UNIT  WITH  THIS  MANUAL.
!