SERVICE MANUAL
Model: HRF-628AF6/IF6
27
Issue 2013-04-07
REF. Ref1304S001V0
Error code list:
NO Malfunction
Error
Indicator
Error code meaning
F SET R SET
1 F SNR failure F4 normal F SNR is short circuit or open circuit
2 RT SNR failure normal F2 RT SNR is short circuit or open circuit
3 R1 SNR failure normal F3 R1 SNR is short circuit or open circuit
4 R2 SNR failure normal F8 R2 SNR is short circuit or open circuit
5 D SNR failure normal F6 D SNR is short circuit or open circuit
6 ICE SNR failure normal FC ICE SNR is short circuit or open circuit
7 Freezer fan motor failure normal E1 more than 30 seconds without signal
8 Cooling fan motor failure normal E2 more than 30 seconds without signal
9 failure communication normal E0
No reflect when setting ,between display
PCB and Power PCB no signal transmitted
over 2 min
10 Defrosting system failure normal Ed
can not reach -12 within 2 hours
11 Icemaker failure normal Er icemaker defective
Error code display:
Attention:These error codes cannot be displayed automatically)
Checking method:
Under LOCK status, press “Func.Set” (E)+ “Ref. Temp” (D) for 3 seconds, then display “--” with one
buzzer sound. If there is error codes, the error will be display after another 3 seconds. If no error
codes, it will exit after another 3 seconds.