HSU-18HEA03/R2(DB)-I
Funcitions and Control
Domestic Air Conditioner
14
Strength operation for 15 minutes.
7KHVWUHQJWKRSHUDWLRQVWRSVRU¿QLVKHVDIWHUWKHPLQXWHV
7KHPRGHFKDQJH¿QLVKHVWKHVWUHQJWKRSHUDWLRQ
(QWHULQJµPXWH¶\RXFDQKDYHQRUPDORSHUDWLRQRUVLJQDOFRQWUROVXFKDVWLPLQJWR¿QLVKWKHVWUHQJWK
operation.
When the system is at the automatic option with the strength/ mute function, if the system enters the
cooling mode, the cooling strength/ mute function will be offered; if the system enters the heating mode,
WKHQWKHKHDWLQJVWUHQJWKPXWHIXQFWLRQZLOOEHRIIHUHGLIWKHV\VWHPHQWHUVWKHDLUÀRZPRGHWKHUHZLOO
be no strength/ mute function.
5.1.6 Mute operation
7KHV\VWHPHQWHUVWKHPRGHDIWHUUHFHLYLQJWKHµPXWHVLJQDO¶
D0XWHKHDWLQJWKHDLUÀRZVSHHGLVVOLJKWWKHV\VWHPVHQGVWKHPXWHVLJQDOWRWKHRXWGRRUV\VWHP
E0XWHFRROLQJWKHDLUÀRZVSHHGLVVOLJKWWKHV\VWHPVHQGVWKHPXWHVLJQDOWRWKHRXWGRRUV\VWHP
:KHQWKHFRPSUHVVRURSHUDWHVWKHDLUÀRZVSHHGLVPXWHVSHHG((3520LVDGDSWDEOH
0XWHRSHUDWLRQFDQQRWZRUNXQGHUWKHGHPRLVWXULQJDQGDLUÀRZVHQGLQJRSHUDWLRQ
5.1.7 Air refreshing
$IWHUUHFHLYLQJWKHVLJQDOIURPWKHUHPRWHFRQWURO+9VHULHVWKHEDFNJURXQGOLJKWRIWKHµKHDOWK¶ORJR
LVJUHHQ+6VHULHVWKHµKHDOWK¶LQGLFDWRU ZLOOEHOLJKWHG,IWKHIDQRSHUDWHVWKHQHJDWLYHLRQJHQHUDWRU
RSHUDWHVWRUHDOL]HWKHQHJDWLYHVHQGLQJIXQFWLRQ
,IWKHLQGRRUIDQVWRSVWKHQHJDWLYHLRQJHQHUDWRULVWXUQHGRII
:KHQWKHQHJDWLYHLRQJHQHUDWRULVWXUQHGRIILIWKHDLUUHIUHVKLQJV\VWHPLVWXUQHGRQWKHQHJDWLYHLRQ
generator will be turned on when the fan operates.
5.1.8 Timing
You can set 24 hours’ on/off timing accordingly. After the setting, the timing indicator will be lightened.
$OVRWKHOLJKWZLOOEHWXUQLQJRIIDIWHUWKHWLPLQJLV¿QLVKHG7KHIROORZLQJVDUHVHYHUDOWLPLQJPHWKRGV
System /on timing: The timing indicator will be lightened and the indoor system is under the waiting
PRGH7KHOLJKWZLOOEHWXUQHGRIIZKHQWKHWLPLQJLV¿QLVKHGDQGWKHUHVWRIWKHV\VWHPZLOORSHUDWHXQGHU
a normal condition. The timing starts since the last reception of the timing singal.
<RXFDQKDYHWKHGRUPDF\VHWWLQJXQGHUWKHWLPLQJPRGHWKHRUGHURI\RXUVHWWLQJVZLOOEHRSHUDWHG
according to the timing settings.
System /off timing: When the system is turned on, the timing indicator is lightened, the rest of the
system will operated under a normal condition. When set time comes, the indicator light will be turned off
DQGWKHV\VWHPZLOOEHWXUQHGRII,I\RXKDYHVHWWKHGRUPDQWIXQFWLRQVWKHRUGHURI\RXUVHWWLQJVZLOOEH
operated according to the timing settings.
System /on and off timing: The settings will be completed according to the orders.
5.1.9 Dormant operation
7KHGRUPDQWWLPLQJLVDQHLJKWKRXUVXQDGDSWDEOHRQH7KHWLPLQJVLJQVDUHVKRZQRQWKH9VHULHV
board. (RC series show the dormant signal, the timing light is lighted on the 6 lights board).
5.1.9.1 Under the cooling/ demoisture operation, after the setting of the dormant operation, the set
temperature will be raised for 1 centigrade after 1 hour’s operation and will be raised for 1 centigrade 1
hour later. The system will keep this status for 6 hours and then close.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Haier HSU-18HEA03/R2(DB)-I and is the answer not in the manual?

Haier HSU-18HEA03/R2(DB)-I Specifications

General IconGeneral
BrandHaier
ModelHSU-18HEA03/R2(DB)-I
CategoryAir Conditioner
LanguageEnglish

Related product manuals