Domestic Air Conditioner
5.Funcitions and Control
5.1 Main functions and control specification of indoor unit
This specification use for HSU12/18VHJ˄DB˅frequency conversion air condition are manufactured
by Haier air condition parent company. "Setting value" (express in parameter) in this specification
means is a parameter that is stored in EEPROM. Refer to [EEPROM parameter table].
5.1.1 Temperature Adjusting function
5.1.1.1 Temperature adjusting of different levels.
(DASH operation conditions under different modes)
5.1.1.2 Select the wind volume when it is set automatic
When the wind volume is automatic, it can be switched between strong, medium and weak according
to the temperature adjusting levels.
Wind volume under the automatic wind volume mode
Temperature adjusting levels
ABCDEFGH I
Heating
Strong Strong Strong Strong Strong Medium Weak Weak SLO
cooling
Strong Strong Strong Medium Medium Weak Weak Weak
Moisture
removing
Strong Medium Medium Medium Weak Weak SLO SLO
COOL
4.0
2.7
2.0
0.7
3.3
1.3
HEAT DASH
4.7
6.34.74.7
B
4.0
2.7
3.3
1.3
2.0
3 MINUTES PROTECTION
COOL DASH
DRY DASH
T
3.7 2.0
1.3
3.0
0.7
1.3
4.3
5.0
5.7
3.3
2.7
4.0
0
COMP. STARTS AGAIN
E
G
F
H
D
C
0.7
3.3
4.0
2.0
2.7
3.7
3.0
1.3
5.0
4.3
5.7
COOLDRY HEAT
(
BLOCK
A
HEAT
5.3
DRY
<120s
19
HSU12/18VHJ(DB)