Domestic Air Conditioner
˄A˅
NO 
YES
Yes 
Check the status of LED1 
on the indoor mainboard. If 
the LED1 blinks 
No 
If the voltage is of a 
constant value of 0V 
DCto5V DC 
Yes 
measure the voltage between 
Jumpers 3 and 4 of IC8 on the indoor 
mainboard with a multimeter. 
NO 
The outdoor mainboard is 
damaged; Replace them with a 
new one. 
If the LED1 is off within two minutes
after the machine is supplied with
power, measure the AC voltage
between positions 1 and 3 on the
terminal of outdoor unit with a
multimeter. 
If 230VAC is available bu
310DC not, the power module is
damaged, replace it with a ne
one. 
Test the outdoor power supply
(230VAC and +310VDC) with a
multimeter. 
The outdoor mainboard is damaged;
replace it with a new one. 
The indoor mainboard is
damaged; replace it with a ne
one. 
If the value varies between 0 and 80 
VAC, the outdoor mainboard is 
damaged, replace it with a new one. 
If the value is constant at about 30V,
the indoor mainboard is damaged,
replace it with a new one. 
If both 230VAC and 310DC
are available, measure
+12V(from7805)is available. 
HSU12/18VHJ(DB)
        Functions and control