7
These values will be written every 10 seconds to a comma
separatedvaluelestoredintherootfolderoftheUSBashdrive.
Eachdayanewcommaseparatedvaluelewillbecreatedfor
storingthesamplesforthatday.Commaseparatedvalueles
older than 60 days will be automatically deleted.
2. USB Event History
WhenaUSBashdriveisinstalledinthecontrolleritwillbegin
to automatically log all dryer events: power loss, power recovery,
alarms, state (standby/running), and mode (manual/scheduled/
remote).
Events are timestamped and recorded in the EVENT.TXT le
storedintherootfolderoftheUSBashdrive.
3. USB Bootloader
Firmware updates for the EMM connect can be performed via the
USBashdrive.Inordertoperformarmwareupdate;placethe
image.hexandlang.hexlesprovidedbySPXintherootfolder
of a USB thumb drive.
WiththedryercontrollerpoweredoffinstalltheUSBashdrive
in the USB host port on the EMM connect. Then while holding
the enter button on the front panel apply power to the controller.
Once the power LED begins blinking rapidly you can release
the enter button. The controller will reboot when the update is
complete.Onstartupthecurrentrmwareversionwillbeshown
on the text display.