Describes the functions of the front panel keys for the HI 8510.
Explains the purpose of the calibration trimmers for the HI 8510.
Describes the functions of the front panel keys for the HI 8512.
Explains the purpose of the calibration trimmers for the HI 8512.
Describes the functions of the front panel keys for the HI 8710.
Explains the purpose of the calibration and alarm trimmers for the HI 8710.
Details calibration and alarm adjustment trimmers for the HI 8710.
Explains the meaning of LED indicators for the HI 8710.
Describes the functions of the front panel keys for the HI 8711.
Explains the purpose of calibration, slope, and set point trimmers for the HI 8711.
Explains calibration, slope, and set point adjustment trimmers for the HI 8711.
Explains the meaning of LED indicators for the HI 8711.
Describes the functions of the front panel keys for the HI 8720.
Explains the purpose of calibration and alarm trimmers for the HI 8720.
Explains calibration and set point adjustment trimmers for the HI 8720.
Explains the meaning of LED indicators for the HI 8720.
Describes the functions of the front panel keys for the HI 931500.
Explains calibration and set point trimmers for the HI 931500.
Describes the functions of the front panel keys for the HI 931501.
Explains calibration and set point trimmers for the HI 931501.
Explains calibration and set point adjustment trimmers for the HI 931501.
Explains the meaning of LED indicators for the HI 931501.
Describes the functions of the front panel keys for the HI 932500.
Explains calibration and set point trimmers for the HI 932500.
How to set the working point for pH or ORP dosage using SET and trimmer controls.
How to set the working point for base dosage using BASE SET and trimmer controls.
How to set the alarm tolerance using the AAL key and trimmer.
Test to verify the mV response of the pH electrode using a buffer solution.
Verifies the internal circuit in terms of offset compensation using pH 7 TEST.
Verifies the amplifier circuit of the meter using pH 4 TEST.
Verifies instrument calibration at point 0 mV using the 0 mV TEST key.
Verifies the slope at point 500 mV using the 500 mV TEST key.
Initial steps for preparing electrodes, including removing protective caps and handling salt deposits.
Instructions for inspecting electrodes, cables, and connectors, and refilling electrodes.
Specific solutions and methods for cleaning electrodes based on contamination type.
Addresses issues like noise, clogged junctions, dry membranes, drifting, and slope problems.
Guidelines for indoor installations up to 10 meters with conventional electrodes.