HARDY MANUFACTURING CO., INC (MODEL H3, H5, & H6) PAGE 1
SECTION I
GENERAL INFORMATION
1 – 1 Specifications
Type of fuel Wood
For outdoor use only
Underwriters Laboratories Inc. Listed – 84E4
Electrical Rating 115 VAC/ 60 HZ / 1P
MFS-15 AMP, MCA-15 AMP
Clearance to Combustibles
Top, Rear, Sides 18”
Chimney Connector 18”
Front 48”
Flooring Non Combustible
Water Capacity
H3 – Holds Approximately 100 Gallons of Water
H5 – Holds Approximately 130 Gallons of Water
H6 – Holds Approximately 60 Gallons of Water
HEATER DIMENSIONS
Description Wide Depth Height Weight
H3 – 120,000 BTU 30” 52 ½” 59 ½” 650 lbs.
H5 – 180,000 BTU 40” 52 ½” 59 ½” 850 lbs.
H6 – 100,000 BTU 30” 40 ½” 51 ½” 475 lbs.
FIREBOX SIZES
Description Wide Depth Height
H3 – 120,000 BTU 24” 32” 36” + 8” for Grates
H5 – 180,000 BTU 34” 32” 36” + 8” for Grates
H6 – 100,000 BTU 24” 24” 36” + 8” for Grates

Related product manuals