2 Installation
di
ital
Revision C • 1/04
HARRIS CORPORATION
2-29
SETUP
SS
SS
S
etup —etup —
etup —etup —
etup — These eight DIP switches set logic functionality for the module per the Switch
Definitions table below.
# Switch Name ON Function (set to operator’s left) OFF Function (set to operator's right)
1 Signal Source Digital Analog
2 Timer Reset Resets timer at module on No timer reset
3 Bypass Sample Rate Bypasses internal SRC (use only when Uses internal SRC (normal setting)
Converter (SRC) the console and all the audio sources
are locked to an external reference)
1
4 Source Type Switcher (VistaMax or External RLS) Direct
5 Switcher Type VistaMax (see Appdx. A about other routers) External RLS (PRE99-947)
6 Spare Switch
7 Input Level Set See table below See table below
8 Input Level Set See table below See table below
REMOTE LINE SELECTOR (RLS) MODULE SWITCHES
78 Analog
2
Digital
3
Off Off +4 dBu 0 dB
Off On +6 dBu -6 dB
On Off +8 dBu -12 dB
On On -10 dBV -18 dB
1
Refer to page 2-11, Digital Clock Reference for details.
2
The nominal analog input to achieve -20 FSD (equal to a +4 dBu output), with the fader set to the red reference line.
3
The amount of gain reduction applied to the digital input.
Remote Line Selector (RLS) Module Switch Definitions
SETUP — Switches 7 and 8
These switches are used together to set the nominal reference level for the inputs. The factory default
settings are both OFF.