COMPONENT FUNCTION/DESCRIPTION
TP6 Antenna phase angle detector, voltage sample, used during phase angle detector adjustment.
TP5 Antenna phase angle detector, current sample, used during phase angle detector adjustment.
TP1 Bandpass Filter phase angle detector, voltage sample, used during phase angle detector adjustment.
TP10 Bandpass Filter phase angle detector, current sample, used during phase angle detector adjustment.
TP7 +5 Volt regulator output test point.
TP2 -5 Volt regulator output test point.
TP4 Antenna Threshold test point (Reference voltage for Antenna VSWR comparator).
TP3 Filter Threshold test point (Reference voltage for Bandpass Filter VSWR comparator).
Table H-2. Output Monitor Board A27, Test Points
See Figure H-2
DX-25U
H-6 888-2297-002 Rev. R: 11-11-96
WARNING: Disconnect primary power prior to servicing. 10/14/1999