EasyManua.ls Logo

Harris DX 25U - Frequency Change Procedure; Frequency Determined Components; Frequency Determined Jumpers and Switches; Output Network Dry Tune

Default Icon
274 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WARNING
ENSURE ALL PRIMARY AC VOLTAGE HAS BEEN REMOVED
FROM TRANSMITTER AND A GROUNDING STICK IS USED TO
GROUND ALL POINTS WHERE AC OR RF POWER HAS BEEN
APPLIED BEFORE PROCEEDING WITH THE FOLLOWING PRO-
CEDURE.
g. Remove the Driver Supply Regulator clear protective
cover and remove the external meter connections.
h. Replace the Driver Supply Regulator clear protective
cover.
5.7 Frequency Change Procedure
The following is a step by step procedure for changing the
frequency of the transmitter. If a complete frequency change is
desired this procedure can be followed in order. If only a specific
tuning procedure is desired (ex. Driver tuning) then only that
section needs to be looked at. In some cases, time is a considera-
tion in changing frequency of the transmitter. To allow a faster
frequency change, procedures which are performed to achieve
optimum transmitter performance, yet are not critical to the
reliable operation of the transmitter, are covered after the section
on Basic Frequency Change.
5.7.1
Test Equipment Required for Frequency Change
The following is a list of the test equipment required to perform
a frequency change. A frequency changeshould notbe attempted
unless the proper equipment is used.
Audio Generator and Distortion Analyzer
Oscilloscope
Frequency Counter
Modulation Monitor
Digital Multimeter (preferred)
Vector Impedance meter or Impedance Bridge
Frequency programmable RF Generator (must operate up
to 3 times carrier frequency)
RF Load, 125 kW average dissipation
Function Generator (optional)
NOTE
Output Network setup can be performed with a Vector Impedance
Meter or Impedance Bridge and RF Generator. A Vector Imped-
ance Meter is usually faster but can be sensitive to interference.
An Impedance Bridge can be more effective in an RF environ-
ment.
5.7.2 Frequency Determined Components
Refer to the FD Chart, 839-7855-137, in the Drawing Package.
Install all the proper parts listed for the new desired frequency.
Oscillator crystal frequencies and part numbers are on drawing
817-1280-025.
Note that the FD chart for the output network components is
organized in bands A through L. The mounting hardware, straps,
plates, etc. are all listed on the parts list. When installing these
components,makesureallconnections aretight.Usespecialcare
when handling vacuum capacitors.
5.7.3
Frequency Determined Jumpers and Switches
Refer to the Tuning Chart, 839-7855-140, in the Drawing Pack-
age. Many of the frequency determined components on the
transmitter are permanently installed and are changed by moving
the desired jumper, coil tap or switch position. The Frequency
Tuning chart lists all jumpers, taps, and switches that need to be
set per frequency. Some of these settings are considered presets
and may need to change during a specific procedure. A list of
boards with frequency determined jumpers, taps, preset adjust-
ments, and switches is shown in Table 5-7.
5.7.4
Output Network Dry Tune
Presetall output network taps accordingto theFrequencyTuning
chart with all FD capacitorsin place. Ifahigh powerdummy load
is not available, a small terminating 50 Ohm resistor can be used.
WARNING
ENSURE ALL PRIMARY AC VOLTAGE HAS BEEN REMOVED
FROM TRANSMITTER AND A GROUNDING STICK IS USED TO
GROUND ALL POINTS WHERE AC OR RF POWER HAS BEEN
APPLIED BEFORE PROCEEDING WITH THE FOLLOWING PRO-
CEDURE.
Using a Vector Impedancemeter or ImpedanceBridge, adjust the
following output network sections to their appropriate X
C
or X
L
values at the desired carrier frequency. The sections should be
isolated (disconnected) from the rest of the other components
and only the necessary connecting straps and hardware should
be used to make the measurements. See table below.
2C2
13-90, 0 -j13 (2C2A and
2C2B capacitors only)
2C4
75-90, 0 -j75 (2C4A and
2C4B capacitors only)
2L3
4290, 0 + j42 (2L3 coil
only)
At frequencies where C5 is installed in series with 2L3:
Adjust 2L3for A+90 or 0 + jA where A = 100,000/(1.257
x Fo) + 42.
BOARD
FREQUENCY
DETERMINED
PRESETS
ANALOG INPUT A35 R85, R84, R43
OSCILLATOR A17 P2, S1, J3
A TO D CONVERTER A34 P10, S1
OUTPUT MONITOR A27 S1, S2, S6, S7, S9, P2
DRIVER COMBINER A14 J14, J15, J16-J32
BINARY COMBINER A8 J30-J33, L1-L16
MAIN COMBINERS A5 thru A7 L1-L16
SWITCH/METER PANEL A31 R1, R2
LED BOARD A32 R41, R67
DC REGULATOR A30 R51, R93
Table 5-7. Frequency Determined Jumpers and Switches
Section V - Maintenance
Rev. Z1: 06-02-00 Additional info to ECN 46105 888-2297-002 5-15
WARNING: Disconnect primary power prior to servicing.

Table of Contents

Related product manuals