K.5.2.3.1 Troubleshooting the Frequency Divider
The Synchronous Binary Counter,U29, divides the input by four
at pin 14. In this circuit, this output is fed back to the clock input
to get the divide by 2 function.
To check operation of U29, turn the Power Amplifier stage
OFF by placing the PA OFF switch S5 on the Controller in the
OFF (UP) position.
Removethe jumper plug atP10,andusea dual-traceoscilloscope
to observe input and outputs from U29. The output at U29-14
should be TTL level logic pulses at one-fourth the input fre-
quency.
K.5.2.4 EOC-L FAULT
Use a dual trace oscilloscope to compare timing of signals at TP3
and TP5. If the EOC status output of U2 at TP5 is still HIGH
when the next START CONVERT pulse at TP3 occurs the
EOC-L signal at U13-4 will stay LOW. This would indicate a
fault in A/D converter IC U2.
K.5.2.5 POWER UP RESET-L FAULT
Measurethe voltage at U12-13.There should bea+5 VDC signal
presentwhentheLowVoltageisON.Ifthereisno +5VDCsignal
and the +5 VDC supply at TP15 measures correctly, capacitor
C41 may be faulty. If there is a +5 VDC signal at U12-13, but
TP1 is logic LOW, replace U12.
K.6 Technical Assistance
See Technical Assistance clause on back of title page.
K.7 Replaceable Parts Service
See Replaceable Parts Service clause on back of title page.
Component Function/Description
DS1 illuminates when an A to D converter failure
occurs. This indication is also available on the
Status Indicator Panel and at the External
Interface
F1 Protects the +22 V supply from +15 V
regulator faults.
F2 Protects the +8 V supply from +5 V regulator
faults
F3 Protects the -22 V supply from -15 V regulator
faults
JP10 Selects division ratio for A/D sample ( divide
by 1, 2 or 3). Refer to schematic diagram or
Frequency Determined Components chart.
JP11 Enables RF sample phase correction circuit
when in position 1-2 and 3-4
R78 Adjust pulse width of ENCODE signal to the
A/D converter
R7 Compensates for voltage offset errors in the
A/D converter
S1 Frequency determined adjustment; adjusts RF
sample phase to switch PA Modules on or off
at the RF zero crossings
S2 Sections A and B are open in the DX 10
Section A is closed in the DX 25.
S2A and S2B are closed in the DX 50.
TableK-1.AnalogtoDigitalBoardA34
Controls and Indicators
Component Function/Description
TP1 Audio + DC, analog signal that is converted
to digital in the A/D chip
TP2 POWER UP RESET-L, logic signal thats
active low
TP3 ENCODE, logic signal that tells the A/D chip
to do a conversion
TP4 +15 V FAULT-L, 0 Volts when the +15 V is
not working
TP5 DAV, logic signal thatslowwhentheA/D
conversion is done
TP6 CLOCK, logic signal that is used to create
the ENCODE pulse
TP7 LATCH STROBE, logic signal that stores
data in latches U3 and U4
TP8 logic signal thats low when A/D ERROR-L
or CLK ERROR-L is low
TP9 Unfiltered reconstructed audio signa
TP10 AA Ground (reconstructed audio signal
ground)
TP11 + 5 V FAULT-L, 0 Volts when the + 5 V is
not working
TP12 -15 V regulator output
TP13 +15 V regulator output
TP14 -15 V FAULT-L, -20 Volts when the -15 V is
not working
TP15 +5 V regulator output
TP16 B Ground (analog ground)
TP17 CLEAR-L, logic signal thatsactivelow
TP18 B Ground (analog ground)
TP19 A Ground (digital ground)
TP20 A Ground (digital ground)
TP21 A Ground (digital ground)
TP22 -5V regulator output
TableK-2.AnalogtoDigitalBoardA34
Test Po ints
Section K - Analog to Digital Converter (A34)
Rev. X: 05-13-98 888-2297-002 K-5
WARNING: Disconnect primary power prior to servicing.

Table of Contents